Accueil
A partir de cette page vous pouvez :
Retourner au premier écran avec les dernières notices... |
Résultat de la recherche
2 résultat(s) recherche sur le mot-clé 'التحليل الطيفي'
Affiner la recherche Faire une suggestion
EVALUATING DIFFERENT ASPECTS OF MATRIX EFFECT ON PHARMACEUTICAL DRUG ANALYSIS THROUGH THE ASSOCIATION OF VIBRATIONAL SPECTROSCOPY TECHNIQUES TO CHEMOMETRIC TOOLS / Mohammed ALAOUI MANSOURI
Titre : EVALUATING DIFFERENT ASPECTS OF MATRIX EFFECT ON PHARMACEUTICAL DRUG ANALYSIS THROUGH THE ASSOCIATION OF VIBRATIONAL SPECTROSCOPY TECHNIQUES TO CHEMOMETRIC TOOLS Type de document : thèse Auteurs : Mohammed ALAOUI MANSOURI, Auteur Année de publication : 2021 Langues : Anglais (eng) Mots-clés : Matrix effect Vibrational spectroscopy chemometrics pharmaceutical drug analysis Effet de matrice Chimiométrie spectroscopie vibrationnelle analyses pharmaceutiques التحليلات الصيدلانية المقاربات الكيميائية التحليل الطيفي تأثير السواغات Résumé : The aim of this thesis was to investigate the ability of the association of vibrational spectroscopic techniques to chemometric tools in order to overcome three different aspects of matrix and interference effects for qualitative and quantitative pharmaceutical drug analysis. The first aspect was focused on testing the ability of applying Partial Least Squares-Discriminant Analysis (PLS-DA) to each of Fourier transform infrared spectroscopy (FT-IR) and Fourier transform near infrared spectroscopy (FT-NIR) to discriminate between different pharmaceutical products based on three main polymorphic forms of the fluconazole. PLS-DA showed its ability to discriminate between samples that have only one of three polymorphic forms of fluconazole. While in case of the matrix effect, which is represented in the existence of two polymorphic in the same sample, PLS-DA showed its limit to do the right discrimination. Thus, another approach is known by Hotelling’s T² and Q residuals joined PLS-DA to detect these samples with two polymorphic forms as outliers. The second aspect of matrix effect focused mainly on evaluating the application each of PLS regression and Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) model on FT-NIR data to quantify ciprofloxacin in different brands of pharmaceutical products. When it comes to quantify ciprofloxacin in samples with the same composition, the obtained results based on Root Mean Squares Error of Prediction (RMSEP) and Relative Errors (RE) proved that both of regression approaches of PLS regression and MCR-ALS are able to carry out the quantitation of the drug substance accurately. However, the quantitation of ciprofloxacin whether in mixtures of different matrix composition or in different brands of pharmaceutical products clearly showed the limit of PLS regression because of the matrix effect, whereas the MCR-ALS based on its low relative and prediction errors, has shown its ability to overcome the problem of the change in the matrix composition due to its second order advantage. The third and last aspect of interference effect aims to investigate a special property of Raman spectroscopy to quantify the ibuprofen in a ternary mixture through an interference polypropylene container. This property of Raman spectroscopy is known by Spatially Offset Raman Scattering (SORS), which allows the monochromatic laser to pass through the packaging and obtain the spectrum of what is inside the container. This investigation was carried out through a comparison study between backscattering (conventional) and SORS mode to quantify ibuprofen through the interference of polypropylene packaging by evaluating the PLS regression models with mean of accuracy profiles following the ICH Q2 (R1) guidelines on validation with ±15% as acceptance limits. Based on the obtained accuracy profiles, the SORS mode demonstrated its ability to quantify accurately through the interference which is not in case of backscattering mode.
Keywords: Matrix effect; Polymorphism; PLS-DA; Hotelling’s T² and Q residuals; PLS regression, MCR-ALS; SORS; FT-IR; FT-NIR; Raman spectroscopyNuméro (Thèse ou Mémoire) : D0262021 Président : Yahia CHERRAH ; Philippe Hubert Directeur : Abdelaziz Bouklouze ; Roland Marini Juge : BOUATIA MUSTAPHA Juge : Mohamadine ElMrabet Juge : Khalid Digua ; Eric Ziemons EVALUATING DIFFERENT ASPECTS OF MATRIX EFFECT ON PHARMACEUTICAL DRUG ANALYSIS THROUGH THE ASSOCIATION OF VIBRATIONAL SPECTROSCOPY TECHNIQUES TO CHEMOMETRIC TOOLS [thèse] / Mohammed ALAOUI MANSOURI, Auteur . - 2021.
Langues : Anglais (eng)
Mots-clés : Matrix effect Vibrational spectroscopy chemometrics pharmaceutical drug analysis Effet de matrice Chimiométrie spectroscopie vibrationnelle analyses pharmaceutiques التحليلات الصيدلانية المقاربات الكيميائية التحليل الطيفي تأثير السواغات Résumé : The aim of this thesis was to investigate the ability of the association of vibrational spectroscopic techniques to chemometric tools in order to overcome three different aspects of matrix and interference effects for qualitative and quantitative pharmaceutical drug analysis. The first aspect was focused on testing the ability of applying Partial Least Squares-Discriminant Analysis (PLS-DA) to each of Fourier transform infrared spectroscopy (FT-IR) and Fourier transform near infrared spectroscopy (FT-NIR) to discriminate between different pharmaceutical products based on three main polymorphic forms of the fluconazole. PLS-DA showed its ability to discriminate between samples that have only one of three polymorphic forms of fluconazole. While in case of the matrix effect, which is represented in the existence of two polymorphic in the same sample, PLS-DA showed its limit to do the right discrimination. Thus, another approach is known by Hotelling’s T² and Q residuals joined PLS-DA to detect these samples with two polymorphic forms as outliers. The second aspect of matrix effect focused mainly on evaluating the application each of PLS regression and Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) model on FT-NIR data to quantify ciprofloxacin in different brands of pharmaceutical products. When it comes to quantify ciprofloxacin in samples with the same composition, the obtained results based on Root Mean Squares Error of Prediction (RMSEP) and Relative Errors (RE) proved that both of regression approaches of PLS regression and MCR-ALS are able to carry out the quantitation of the drug substance accurately. However, the quantitation of ciprofloxacin whether in mixtures of different matrix composition or in different brands of pharmaceutical products clearly showed the limit of PLS regression because of the matrix effect, whereas the MCR-ALS based on its low relative and prediction errors, has shown its ability to overcome the problem of the change in the matrix composition due to its second order advantage. The third and last aspect of interference effect aims to investigate a special property of Raman spectroscopy to quantify the ibuprofen in a ternary mixture through an interference polypropylene container. This property of Raman spectroscopy is known by Spatially Offset Raman Scattering (SORS), which allows the monochromatic laser to pass through the packaging and obtain the spectrum of what is inside the container. This investigation was carried out through a comparison study between backscattering (conventional) and SORS mode to quantify ibuprofen through the interference of polypropylene packaging by evaluating the PLS regression models with mean of accuracy profiles following the ICH Q2 (R1) guidelines on validation with ±15% as acceptance limits. Based on the obtained accuracy profiles, the SORS mode demonstrated its ability to quantify accurately through the interference which is not in case of backscattering mode.
Keywords: Matrix effect; Polymorphism; PLS-DA; Hotelling’s T² and Q residuals; PLS regression, MCR-ALS; SORS; FT-IR; FT-NIR; Raman spectroscopyNuméro (Thèse ou Mémoire) : D0262021 Président : Yahia CHERRAH ; Philippe Hubert Directeur : Abdelaziz Bouklouze ; Roland Marini Juge : BOUATIA MUSTAPHA Juge : Mohamadine ElMrabet Juge : Khalid Digua ; Eric Ziemons Réservation
Réserver ce document
Exemplaires
Code barre Cote Support Localisation Section Disponibilité D0262021 WA Thèse imprimé Unité des Thèses et Mémoires Doctorat SVS 2021 Disponible Documents numériques
D0262021URL INTEGRATION DE LA CARTOGRAPHIE METABOLIQUE PAR RESONANCE MAGNETIQUE AU PLANNING RADIOCHIRURGICAL PAR LEKSELL GAMMAPLAN / DERKAOUI HASSANI FAHD
Titre : INTEGRATION DE LA CARTOGRAPHIE METABOLIQUE PAR RESONANCE MAGNETIQUE AU PLANNING RADIOCHIRURGICAL PAR LEKSELL GAMMAPLAN Type de document : thèse Auteurs : DERKAOUI HASSANI FAHD, Auteur Année de publication : 2019 Langues : Français (fre) Mots-clés : Radiochirurgie reverse engineering Leksell GammaPlan spectroscopie résonance
magnétique cartographie métabolique planning radiochirurgical Radiosurgery reverse engineering Leksell GammaPlan MRI spectroscopy metabolic
cartography radiosurgical plan التصوير الإشعاعي الهندسة العكسية خطة ليكسل التحليل الطيفي الرنين المغناطيسي رسم خرائط الاستقلاب بالرنين المغناطيسي التخطيط الإشعاعيRésumé : La spectroscopie multivoxelle par résonnance magnétique a démontré son apport clinique pour
la prise de décision en matière de stratégie thérapeutique pour les tumeurs cérébrales. Cependant son
grand apport reste non exploité en radiochirurgie à cause d’une incompatibilité entre les images DICOM
obtenues par imagerie par résonance magnétique et le logiciel de planning radiochirurgical Leksell
GammaPlan particulièrement dans les tumeurs cérébrales intra-axiales infiltrantes. Le but de cette étude
est de développer une solution informatique pour permettre l’intégration de la cartographie métabolique
par résonance magnétique sur le planning radiochirurgical par Leksell GammaPlan dans la pratique
habituelle d’un radiochirurgien pour un meilleur ciblage des zones tumorales actives.
En utilisant la méthodologie du Reverse engineering, les images DICOM de la spectroscopie
multivoxelle ont été analysé. Nous avons défini les métadonnées de ces images dont le changement
permettra de rendre ces images compatibles avec Leksell GammaPlan. En utilisant le langage de
programmation Python, nous avons développé une nouvelle solution informatique permettant d’agir sur
les métadonnées des images assurant ainsi une conversion automatisée et la création d’images DICOM
compatibles avec Leksell GammaPlan.
Nous avons créé un nouveau logiciel, « GP Adapting Solution » qui va permettre de convertir
les images DICOM produites par imagerie par résonance magnétique initialement incompatibles avec
Leksell GammaPlan en images compatibles avec cette plateforme de planning radiochirurgical.
Ce travail a permis de résoudre le problème d’incompatibilité des images de cartographie
métabolique avec Leksell GammaPlan et de créer un logiciel intégré et adapté à la pratique
neurochirurgicale en radiochirurgie. Cela représente une première étape pour profiter des données des
plusieurs modalités d’IRM jusque-là étrangère à la pratique radiochirurgicale de routine permettant ainsi
une nouvelle approche dans le planning radiochirurgical des tumeurs cérébrales.Numéro (Thèse ou Mémoire) : D0092019 Président : Abdessamad El Ouahab Directeur : Adyl Melhaoui Juge : Najia El Abbadi Juge : Yasser Arkha Juge : Mohammed Jiddane ; Abdelhakim Lakhdar INTEGRATION DE LA CARTOGRAPHIE METABOLIQUE PAR RESONANCE MAGNETIQUE AU PLANNING RADIOCHIRURGICAL PAR LEKSELL GAMMAPLAN [thèse] / DERKAOUI HASSANI FAHD, Auteur . - 2019.
Langues : Français (fre)
Mots-clés : Radiochirurgie reverse engineering Leksell GammaPlan spectroscopie résonance
magnétique cartographie métabolique planning radiochirurgical Radiosurgery reverse engineering Leksell GammaPlan MRI spectroscopy metabolic
cartography radiosurgical plan التصوير الإشعاعي الهندسة العكسية خطة ليكسل التحليل الطيفي الرنين المغناطيسي رسم خرائط الاستقلاب بالرنين المغناطيسي التخطيط الإشعاعيRésumé : La spectroscopie multivoxelle par résonnance magnétique a démontré son apport clinique pour
la prise de décision en matière de stratégie thérapeutique pour les tumeurs cérébrales. Cependant son
grand apport reste non exploité en radiochirurgie à cause d’une incompatibilité entre les images DICOM
obtenues par imagerie par résonance magnétique et le logiciel de planning radiochirurgical Leksell
GammaPlan particulièrement dans les tumeurs cérébrales intra-axiales infiltrantes. Le but de cette étude
est de développer une solution informatique pour permettre l’intégration de la cartographie métabolique
par résonance magnétique sur le planning radiochirurgical par Leksell GammaPlan dans la pratique
habituelle d’un radiochirurgien pour un meilleur ciblage des zones tumorales actives.
En utilisant la méthodologie du Reverse engineering, les images DICOM de la spectroscopie
multivoxelle ont été analysé. Nous avons défini les métadonnées de ces images dont le changement
permettra de rendre ces images compatibles avec Leksell GammaPlan. En utilisant le langage de
programmation Python, nous avons développé une nouvelle solution informatique permettant d’agir sur
les métadonnées des images assurant ainsi une conversion automatisée et la création d’images DICOM
compatibles avec Leksell GammaPlan.
Nous avons créé un nouveau logiciel, « GP Adapting Solution » qui va permettre de convertir
les images DICOM produites par imagerie par résonance magnétique initialement incompatibles avec
Leksell GammaPlan en images compatibles avec cette plateforme de planning radiochirurgical.
Ce travail a permis de résoudre le problème d’incompatibilité des images de cartographie
métabolique avec Leksell GammaPlan et de créer un logiciel intégré et adapté à la pratique
neurochirurgicale en radiochirurgie. Cela représente une première étape pour profiter des données des
plusieurs modalités d’IRM jusque-là étrangère à la pratique radiochirurgicale de routine permettant ainsi
une nouvelle approche dans le planning radiochirurgical des tumeurs cérébrales.Numéro (Thèse ou Mémoire) : D0092019 Président : Abdessamad El Ouahab Directeur : Adyl Melhaoui Juge : Najia El Abbadi Juge : Yasser Arkha Juge : Mohammed Jiddane ; Abdelhakim Lakhdar Réservation
Réserver ce document
Exemplaires
Code barre Cote Support Localisation Section Disponibilité D0092019 WA Thèse imprimé Unité des Thèses et Mémoires Doctorat SVS 2019 Disponible